"Bfi Automation" markasına ait modeller;
6013-2031-00
 Former article no.: S 520.3
 Compact flame detector CFC2000UV
 Relay and 0/4-20mA output
 Two-channel compact system for continuous monitoring
 of gas and oil burners of any power with additional
 Frequency analysis for better selectivity. The compact
 Flame detector is equipped with a semiconductor sensor
 whose spectral sensitivity lies in the UV range.
 Electronic self-monitoring guarantees safe operation.
 Flame intensity and the status of the flame relay are
 LEDs. The safety shutdown time can be set via a jumper
 predefined and set via software (1-5s).
 Sensitivity, ON/OFF level and switch-on delay are controlled by
 Software discontinued. An online frequency analysis and visualization
 of the flame radiation is possible with the BFI software.
 Further technical details:
 Two separate and adjustable sensitivity levels
 Potential-free changeover contact for the flame ON/OFF signals.
 Flame relay: potential-free changeover contact
 max. 48V switching voltage
 max. 1A switching current
 max. 30W switching power
 Flame signal output: 0/4-20mA (Ra <250Ohm)
 Spectral range: 280 to 420 nm
 Operating mode: Continuous operation
 Viewing angle: 2.7°
 Self-test: once in 800ms
 Supply voltage: 24V DC
 Current consumption: approx. 200mA
 Ambient temperature: -20 to +70°C.
 Data transmission: RS232/infrared interface
 Electrical connection: Harting connector 90°
 Dimensions [mm]: L 235 x W 108 x H 190 mm
 Housing: aluminum, RAL5010, IP65
 ATEX Zone: II 3G Ex ec nC II T4 Gc
 SIL: SIL3
6013-2031-00

Bfi Automation
6013-2031-00 Former article no.: S 520.3 Compact flame detector CFC2000UV Relay and 0/4-20mA output Two-channel compact system for continuous monitoring of gas and oil burners of any power with additional Frequency analysis for better selectivity. The compact Flame detector is equipped with a semiconductor sensor whose spectral sensitivity lies in the UV range. Electronic self-monitoring guarantees safe operation. Flame intensity and the status of the flame relay are LEDs. The safety shutdown time can be set via a jumper predefined and set via software (1-5s). Sensitivity, ON/OFF level and switch-on delay are controlled by Software discontinued. An online frequency analysis and visualization of the flame radiation is possible with the BFI software. Further technical details: Two separate and adjustable sensitivity levels Potential-free changeover contact for the flame ON/OFF signals. Flame relay: potential-free changeover contact max. 48V switching voltage max. 1A switching current max. 30W switching power Flame signal output: 0/4-20mA (Ra <250Ohm) Spectral range: 280 to 420 nm Operating mode: Continuous operation Viewing angle: 2.7° Self-test: once in 800ms Supply voltage: 24V DC Current consumption: approx. 200mA Ambient temperature: -20 to +70°C. Data transmission: RS232/infrared interface Electrical connection: Harting connector 90° Dimensions [mm]: L 235 x W 108 x H 190 mm Housing: aluminum, RAL5010, IP65 ATEX Zone: II 3G Ex ec nC II T4 Gc SIL: SIL3