BursterPANEL MOUNT
BursterOptional calibration: Factory calibration certificate for force sensors or Measuring chains. Measuring range end values: 0... 1 N to 0... 200 kN in compression direction, 5 power levels evenly distributed (20% steps). Increasing and decreasing measuring force at unchanged installation position. • Measuring range 5 N, at least 4 force levels). *** Calibration is not possible through the Accreditation of the calibration laboratory. The calibration certificate does not contain accreditation symbol and is therefore not via EA MLA covered.
BursterMONITORING CONTROLLER
Bursterminiature pressure force sensor, Measuring range 0 ... 50 kN, nominal sensitivity, Connection cable length 1.7 m
BursterLoadcell
BursterLOAD CELL
BursterINTERFACE MODULE DIGIFORCE 230VAC 50HZ
BursterINTERFACE MODULE DIGIFORCE 230VAC 47-63HZ
BursterIn-line measuring amplifier for strain gauge sensors, Housing version with plug-in connectors. Range adjustable from 0.8 mV/V to 2.5 mV/V. Analog output +/- 10V.
BursterHigh-precision torque sensor, rotating, measuring range 5 Nm, shaft end without keyway, torque output signal: +/- 10 volts.
BursterDigiControl PC software for DIGIFORCE 9311 PLUS version, scope of the basic version incl. automatic measurement data logging, Protocol assistant and Excel export; Single-user license; Download the latest software version at www.burster.de (product page DIGIFORCE 9311)
BursterDIGIFORCE 9311 in a combined table/panel enclosure Auxiliary power supply 100-240VAC, for strain gauges, potentiometers, standard signals PLC I/O and EtherNet/IP option, interfaces: Ethernet and USB
BursterCalibration of a measuring chain consisting of sensor and measuring amplifier, including calibration protocol Standard 0-10V, sensor in preferred direction
BursterCalibration certificate with accreditation symbol (DAkkS) according to DIN EN ISO 376 for force sensors or Measuring chains in pressure direction. 10 force levels evenly across the measuring range distributed (10% increments). Increasing and decreasing measuring force in different installation positions. For measuring range end values 100 N to 50 kN If the calibration certificate contains a statement of conformity to comply with error limits, so we make the determination only under Consideration of the expanded measurement uncertainty (confidence level 95%), according to ILAC-G8:09/2019, 2019 Appendix B Example 2. This means that conformity with Data sheet information of the calibration object only can be confirmed provided that the measurement deviation plus the amount of the extended Measurement uncertainty within the permissible specification. Conformity statements for device classes that are normative are regulated (DIN 51309 and DIN EN ISO 376)
Burster4420 CALIBRATOR BURSTER UNIVERSAL
Burster: 8524-6020-NFB0S000 Precision tension-compression force sensor, Measuring range 0 ¬ kN, nominal sensitivity, Connection cable length 3 m, Connector type 9900-V209 mounted
Burster