FKPT04V62KCBYYL
Georgin
40492 Pressure sensor 6.25 -
100 bar ATEX
Successor type to FKPT04V52KBY0Y
FKP series pressure sensor
min./max. Sapnne: 6.25 - 100 bar
Maximum pressure (overload limit): 150 bar
Calibration range: *** please
to be specified***
Accuracy: +/- 0.1% of the calibrated
range
Measuring membrane: 316L st.st.
Bride: INOX 316L
filled with silicone oil
Standard application
Process connection: 1/2" - 14 NPTI
Power supply 10.5 - 45 VDC
Electrical connection: 1/2" - 14 NPT
Output signal: 4 - 20 mA
(2-wire technology) + HART
RFI protection according to IEC 801-3
Housing: Aluminum die-cast alloy,
polyester coated
Digital display (customer-specific)
Scaling)
Additionally: st. st. tag plate
equipped with st.st. mounting clamp
for 2-inch pipe
ATEX Information:
certificate DEKRA 14ATEX0016X
Ex ia IIC T5 Ga (-40 <Ta<50°C) Ex ia IIIC
T100°C Da
Ex II 1 GD : Group II (Surface) - Category
1GD
Zones 0-1-2 (Gas) or zones 20-21-22
(Dust)
Production