"Labom" markasına ait modeller;
CI4120 PRESSURE TRANSMITTER PASCAL Ci4 for diaphragm seal operation,
sturdy
process connection bottom
see data sheet D4-016-3
A3166 nominal range: -1...400 bar, Turndown max. 100:1, overload limit 750
bar; sensor type thin film
accuracy: <= 0.10% from adjusted measuring span (Lin./Hys./Rep., up to
Turndown <=5:1 no changes)
F2 parameterizing: see below
device ID: LABOM PASCAL Ci4
lower range value: 0
upper range value: + 250,0000
pressure unit: bar
unit of sensor temperature: °C
damping: 0.0 s
display mode: big display
principle value: pressure
output function: linear
residual current low < 3,6 mA
HART address: 0
H21  output signal: 4...20 mA with HART
S66  Ex design:
TÜV 13 ATEX 120264 X
II 1/2 G, II 2 G Ex ia IIC TX Ga/Gb, Gb
II 1/2 D, II 2 D Ex ia IIIC Txx°C Da/Db, Db
Please pay attention to the application conditions, which can be taken
from
the data sheet and the ex-safety instructions XA_010!
M26.2 high-resolution graphic display with backlight
intuitive 4-button operation, quick access to device data
available languages (english, turkish, german), default setting turkish
Y1 material case: stainless steel mat. no. 1.4301/1.4305 (304/303)
2 material front cover: stainless steel, window non-splittering glass2
degree of protection: IP 65 / IP 67
T20 electrical connection: cable gland M 16 x 1.5, polyamide black, for cable
ø 4.5-10 mm
0 cable clamps: spring clip terminals up to 1.5 mm²
K1086 design: system screwed
DB9001 DIAPHRAGM SEAL for high temperature applications
nominal pressure: PN 400
connection flange: ø 90 mm,
CI4120-A3166-F2-H21-S66-M26.2-Y12-T200-K1086 DB9001-G7-K1-F1-A151-L35

Labom
CI4120 PRESSURE TRANSMITTER PASCAL Ci4 for diaphragm seal operation, sturdy process connection bottom see data sheet D4-016-3 A3166 nominal range: -1...400 bar, Turndown max. 100:1, overload limit 750 bar; sensor type thin film accuracy: <= 0.10% from adjusted measuring span (Lin./Hys./Rep., up to Turndown <=5:1 no changes) F2 parameterizing: see below device ID: LABOM PASCAL Ci4 lower range value: 0 upper range value: + 250,0000 pressure unit: bar unit of sensor temperature: °C damping: 0.0 s display mode: big display principle value: pressure output function: linear residual current low < 3,6 mA HART address: 0 H21 output signal: 4...20 mA with HART S66 Ex design: TÜV 13 ATEX 120264 X II 1/2 G, II 2 G Ex ia IIC TX Ga/Gb, Gb II 1/2 D, II 2 D Ex ia IIIC Txx°C Da/Db, Db Please pay attention to the application conditions, which can be taken from the data sheet and the ex-safety instructions XA_010! M26.2 high-resolution graphic display with backlight intuitive 4-button operation, quick access to device data available languages (english, turkish, german), default setting turkish Y1 material case: stainless steel mat. no. 1.4301/1.4305 (304/303) 2 material front cover: stainless steel, window non-splittering glass2 degree of protection: IP 65 / IP 67 T20 electrical connection: cable gland M 16 x 1.5, polyamide black, for cable ø 4.5-10 mm 0 cable clamps: spring clip terminals up to 1.5 mm² K1086 design: system screwed DB9001 DIAPHRAGM SEAL for high temperature applications nominal pressure: PN 400 connection flange: ø 90 mm,