M1500 DA SNR: 1309-359
Badger Meter
Transmitter M 1000
for measuring in a fully filled pipeline
For media with a solids content of max. 7% Ts
Installation: assembled / separated with X m cable
Housing: Cast aluminum powder-coated in IP 67
Cable entry: 2 x M 20
Ambient temperature: - 20 to + 60°C
Display: LCD,
Conductivity: min. 5 µS/cm (20 µS/cm for demineralized water)
Outputs:
Analog output: 0/4 - 20 mA / 0 - 10 mA, flow direction is
displayed via a separate status output
Frequency output max. 10 kHz (open collector)
Status output:
min./max. alarm, preset, flow direction, fault message,
freely configurable
Pulse output: 2 open collector, passive 32 VDC, 0-100 Hz 100 mA,
100 - 10,000 Hz 20 mA, optionally active
Configuration: via RS232 or keyboard
Optionally available: Hart / M-Bus / Ethernet (Modbus TCP/IP)
Measuring accuracy: ± 0.3% of measured value; ±2 mm/s of measured value
Reproducibility: 0.1%
Measuring range: 0.03 - 12 m/s
Flow direction: bi-directional possible.
Standard uni-directional (in the direction of the arrow)
Interface: RS232, RS485 and Modbus RTU
Empty pipe detection: On/Off
Medium monitoring via separate electrode
Low flow suppression: 0-10%
Supply: 9 - 36 VDC
1 additional grounding electrode
installed in the flow meter
Material: Hastelloy C
-for non-earthed cables (e.g. plastic)-
1Magnetic-Inductive Flowmeter Type II
Measuring range 0.09 - 2.8 m³/h
Lining PFA, electrodes Hastelloy C
Housing and flanges made of stainless steel 1.4301
Temperature -20...+100°C, pressure max. 16 bar
(-40 ... +150°C with remote display electronics)
Overall length 170 mm, connection flanges DN 10 PN 16