" Badger Meter" markasına ait modeller;
1 transmitter M 1000
 for measuring in a fully filled pipeline
 For media with a solids content of max. 7% Ts
 Installation: assembled / separated with X m cable
 Housing: Cast aluminum powder-coated in IP 67
 Cable entry: 2 x M 20
 Ambient temperature: - 20 to + 60°C
 Display: LCD
 Conductivity: min. 5 µS/cm (20 µS/cm for demineralized water)
 Outputs:
 Analog output: 0/4 - 20 mA / 0 - 10 mA, flow direction is
 displayed via a separate status output
 Frequency output max. 10 kHz (open collector)
 Status output:
 min./max. alarm, preset, flow direction, fault message, freely configurable
 Pulse output: 2 open collector, passive 32 VDC, 0-100 Hz 100 mA,
 100 - 10,000 Hz 20 mA, optionally active
 Configuration: via RS232 or keyboard
 Optionally available: Hart / M-Bus / Ethernet (Modbus TCP/IP)
 Measuring accuracy: ± 0.3% of measured value; ±2 mm/s of measured value
 Reproducibility: 0.1%
 Measuring range: 0.03 - 12 m/s
 Flow direction: bi-directional possible.
 Standard uni-directional (in the direction of the arrow)
 Interface: RS232, RS485 and Modbus RTU
 Empty pipe detection: On/Off; medium monitoring via separate electrode
 Low flow suppression: 0-10%
 Supply: 92 - 275 VAC
 1 additional grounding electrode
 installed in the flow meter
 Material: Hastelloy C
 -for non-earthed cables (e.g. plastic)-
 1Magnetic-Inductive Flowmeter Type II
 Measuring range 1.4 - 45 m³/h
 Lining hard rubber, electrodes Hastelloy C
 Lining with drinking water approval (WRAS certified)
 Housing and flanges: painted steel
 Temperature 0... +80°C, pressure max. 16 bar
 Overall length 200 mm
 Connection flanges DN 40 PN 16
M1000 according to SNR: 1808-361

Badger Meter
1 transmitter M 1000 for measuring in a fully filled pipeline For media with a solids content of max. 7% Ts Installation: assembled / separated with X m cable Housing: Cast aluminum powder-coated in IP 67 Cable entry: 2 x M 20 Ambient temperature: - 20 to + 60°C Display: LCD Conductivity: min. 5 µS/cm (20 µS/cm for demineralized water) Outputs: Analog output: 0/4 - 20 mA / 0 - 10 mA, flow direction is displayed via a separate status output Frequency output max. 10 kHz (open collector) Status output: min./max. alarm, preset, flow direction, fault message, freely configurable Pulse output: 2 open collector, passive 32 VDC, 0-100 Hz 100 mA, 100 - 10,000 Hz 20 mA, optionally active Configuration: via RS232 or keyboard Optionally available: Hart / M-Bus / Ethernet (Modbus TCP/IP) Measuring accuracy: ± 0.3% of measured value; ±2 mm/s of measured value Reproducibility: 0.1% Measuring range: 0.03 - 12 m/s Flow direction: bi-directional possible. Standard uni-directional (in the direction of the arrow) Interface: RS232, RS485 and Modbus RTU Empty pipe detection: On/Off; medium monitoring via separate electrode Low flow suppression: 0-10% Supply: 92 - 275 VAC 1 additional grounding electrode installed in the flow meter Material: Hastelloy C -for non-earthed cables (e.g. plastic)- 1Magnetic-Inductive Flowmeter Type II Measuring range 1.4 - 45 m³/h Lining hard rubber, electrodes Hastelloy C Lining with drinking water approval (WRAS certified) Housing and flanges: painted steel Temperature 0... +80°C, pressure max. 16 bar Overall length 200 mm Connection flanges DN 40 PN 16