Kracht - VC 0,025 G2 K3 R2 SH
763 / 5000
Çeviri sonuçları
Gear flow meter
Housing material stainless steel 1.4404
Material measuring mechanism stainless steel 1.4462
Material O-rings FFKM
Tungsten carbide plain bearings
Product data
Pulse volume 0.025 cm³ / pulse
Line connection pipe connection G1 / 8 "
Electronic output 2 square wave signals, offset by 90 °
Electrical connection plastic angle plug - terminal strip
Standard temperature version
Supply voltage 24 V DC ± 20%
Specific dates
Flow measuring range 0.02 ... 2 l / min
Measuring mechanism start-up at 0.001 l / min
Linearized measuring accuracy ± 3% of the measuring mechanism (with viscosity: min. 100 mm² / s)
Repeatability ± 0.05%
Resolution 40,000 pulses / l
max.permissible pressure 480 bar
Operating medium temperature -15 ° C ... + 80 ° C
Ambient temperature -15 ° C ... + 80 ° C
max. size of foreign particles 30 μm